Clean the circuit. Test the pressure.
Flushing and pressure-testing systems
Haskel systems combining flushing, filtration and pressure testing for industrial assemblies and systems.
FLUSH & TEST SYSTEMS
Main applications
- Flushing and filtration
- Pressure testing
- Assembly maintenance
- Combine two processes
- Flushing and pressure testing in one integrated system.
- Adapt the test
- Test pressure up to 700 bar, according to specification.
- Plan for maintenance
- Component access and control options according to configuration.
Electrical and air requirements will be defined in the specification. The configuration shown also requires a three-phase electrical supply.
Product family technical information ←
Your brochures
Download promotional brochure (PDF) ↓Download technical brochure (PDF) ↓Brochure content is also available to read on this page. The original PDF files have not undergone screen-reader tagging verification.

Original artwork in Hebrew; the publication text is available on this page.
Flushing and pressure testing. In one system.
System and utility data for the configuration described in the brochure
- Maximum test pressure in the configuration shown
- 700 bar
- Compressed-air supply requirement
- 80 psi
- Three-phase power in the configuration shown
- 415 V
Specification and utilities
| Item | Brochure data |
|---|---|
| Maximum test pressure | 10,000 psi / approx.700 bar |
| Electrical supply | 415 V / 50 Hz; three phases and neutral |
| Air supply | 80 psi |
| Working fluids | Fluids of type Transaqua, with compatible materials |
| Component interface | Two flushing outlets; return lines to the main tank |
| Flow rates and tank volume | Not numerically specified in the brochure; to be defined in the system specification |
Testing and flushing are intended for assemblies outside the unit. Connections and return lines will be matched to the component under test.
What does the described configuration include?
- Flushing circuits
- Low- and high-flow circuits at high pressure; pressure filter with bypass and isolation valves before flushing outlets
- Measurement and pressure protection
- Outlet pressure gauge, pressure switch and pressure-limiting valve; optional control by PLC
- Tank and filtration
- Main stainless-steel tank with level and temperature gauges, drain, breather and sensors; separate-circulation filtration circuit and coolers
Data that determines system size
Fluid and desired cleanliness level • Flushing flow • Circuit volume • Test pressure and time • Heat load • Number of components tested simultaneously.
Utility data applies to the brochure configuration. There is no single flow rating for all systems; confirm a specification for the application.
Brochure source: Flush and Test Rigs · pages 1. Data is taken from existing materials; suitability is checked against the model and current manufacturer document.