Solution selection
Home / HASKEL / Gas boosters / AGD-62
HASKEL / Catalogue model

Gas booster AGD-62

AGD-62

HASKEL AGD-62 pneumatically driven gas booster. Select by gas type, inlet conditions, outlet pressure and duty cycle.

01Drive: compressed air
02Configuration: single-stage, double-acting
03Maximum gas supply pressure: 5000 psig / 345 bar
04Minimum gas supply pressure: 200 psig / 14 bar
Product catalogues and documents ↓

The model will be added to your request. The B.N. team will check its suitability for your operating conditions.

AGD-62 — Product family image for illustration
FAMILY IMAGE / HASKEL / TECHNICAL PRODUCT VIEW
APPLICATION & DESIGN

Understand the application.

Applications

  • Filling and transferring gas between vessels
  • Pressure and leak testing
  • Gas charging of hydraulic accumulators
  • Pressurized gas supply to a process

Product features

  • Drive: compressed air
  • Configuration: single-stage, double-acting
  • Maximum gas supply pressure: 5000 psig / 345 bar
  • Minimum gas supply pressure: 200 psig / 14 bar
TECHNICAL DATA

Data with a source.

ParameterValue and reference conditions
DriveCompressed air
ConfigurationSingle-stage, double-acting
Maximum gas supply pressure5000 psig / 345 bar
Minimum gas supply pressure200 psig / 14 bar
Maximum outlet pressure — inert gas9000 psig / 620 bar
Static stall pressure — manufacturer formula60 Pa+Ps
Piston displacement per cycle6.2 in³ / 101.6 ml
Weight according to manufacturer table49 lb / 22 kg
Minimum drive-air pressure20 psi
Maximum drive-air pressure150 psig

Pressure data refer to the manufacturer table and the specified gas configuration. Oxygen or hydrogen use requires an appropriate version, cleaning and certification. In the stall formula, Pa is drive-air pressure and Ps is gas supply pressure; use consistent units and observe all table limits. For two-stage models, check the Interstage Stall limit. Flow curves, connections and service kits are detailed in the attached document.

YOUR APPLICATION

Your data. Our selection.

  • Gas type and composition, purity and seal compatibility
  • Minimum and maximum inlet pressure and target pressure, including units
  • Flow at the operating point or vessel volume and filling time
  • Drive-air pressure and flow, duty cycle and temperature
  • Cleanliness requirements, installation area and tubing connections

You may attach a specification, drawing or nameplate photo. The site assistant can help organize the data.