Solution selection
Home / HASKEL / HIPPO / ASF-60 · WATER
HASKEL / Product family

HIPPO hose test system

HIPPO / ASF-60 · WATER

HIPPO combines pressure generation and a chamber for testing hoses and components. This page shows B.N.'s documented water configuration with an ASF-60 pump; its data are kept separate from the wider HIPPO family envelope.

01Air-driven pump and control circuit
02Test chamber with an interlocked door according to the brochure
03Separate water and oil configurations
04Outlet and control options according to system definition
Product catalogues and documents ↓

The model will be added to your request. The B.N. team will check its suitability for your operating conditions.

HIPPO / ASF-60 · WATER
HASKEL / TECHNICAL PRODUCT VIEW
APPLICATION & DESIGN

Understand the application.

Applications

  • Pressure testing of hydraulic hoses
  • Testing piping assemblies
  • Testing components compatible with chamber dimensions and test specification

Product features

  • Air-driven pump and control circuit
  • Test chamber with an interlocked door according to the brochure
  • Separate water and oil configurations
  • Outlet and control options according to system definition
TECHNICAL DATA

Data with a source.

ParameterValue and reference conditions
Pump in the water configuration shownASF-60
Pressure range in this configuration20–400 barg with 6 barg drive air
Maximum flow in this configuration3 L/min; not achieved at maximum pressure
Standard system dimensions160 × 60 × 130 cm
Test chamber120 × 60 × 70 cm
Air requirement in the brochure0.75 Nm³/min at 6 bar
Electrical supply240 V / 50 Hz — single-phase
Test connection1/2 inch BSP — female

Source: Hippo Hose Test Rig brochure, pages 1–2, as documented in B.N.'s technical publication. Dimensions refer to the standard configuration; not every combination of options is necessarily available. Confirm configuration and revision before ordering.

The brochure also includes other configurations up to 2,000 bar and up to 5 L/min; these are not the performance of the ASF-60 shown and are not achieved simultaneously. Configuration data originate from B.N.'s documented material; configuration, availability and binding revision must be confirmed before ordering.

MODELS & CONFIGURATIONS

Select a model. Explore the details.

Model / seriesFeatures
HIPPO / ASF-60Documented water configuration: 20–400 barg, up to 3 L/min
HIPPO / AW-60The equivalent oil configuration appears in the brochure; confirm the full order specification
YOUR APPLICATION

Your data. Our selection.

  • Dimensions and volume of the component under test
  • Test fluid and required pressure
  • Filling, pressure-rise and hold times
  • Number of outlets and connection types
  • Results recording, controls and available utilities

You may attach a specification, drawing or nameplate photo. The site assistant can help organize the data.