HASKEL / Catalogue modelProduct catalogues and documents ↓
Refrigerant recovery pump 59025
59025
Pneumatic pump for recovery, filling and transfer of liquid and vapor refrigerants. Model 59025 is listed with a dedicated specification and drawing in the manufacturer document.
01Weight according to manufacturer table: 25 lb / 11 kg
02Displacement per cycle: 10 in³
03Air-drive bore × stroke: 5¾ × 2 in
04Wetted metals: Aluminum and Stainless Steel
The model will be added to your request. The B.N. team will check its suitability for your operating conditions.

HASKEL / TECHNICAL PRODUCT VIEW
APPLICATION & DESIGN
Understand the application.
Applications
- Transfer between refrigerant vessels
- Refrigerant recovery during servicing
- Charging refrigeration systems
- Handling liquefied gases after compatibility review
Product features
- Weight according to manufacturer table: 25 lb / 11 kg
- Displacement per cycle: 10 in³
- Air-drive bore × stroke: 5¾ × 2 in
- Wetted metals: Aluminum and Stainless Steel
TECHNICAL DATA
Data with a source.
| Parameter | Value and reference conditions |
|---|---|
| Weight according to manufacturer table | 25 lb / 11 kg |
| Displacement per cycle | 10 in³ |
| Air-drive bore × stroke | 5¾ × 2 in |
| Wetted metals | Aluminum and Stainless Steel |
| Pump seals — standard | Neoprene & PTFE |
| Seal option -2 | Buna N & PTFE |
| Seal option -3 | Viton & PTFE |
Select seals by refrigerant and the document's compatibility table. Performance depends on physical state, inlet/outlet pressures and available air power. Do not assume every refrigerant is compatible with the standard version.
DOCUMENTS & SOURCES
Professional information. Within reach.
Refrigerant recovery pumpsEnglish · PDF · 2 Pages · 1.1 MB · Opens in a new tabManufacturer catalogue — specifications, performance curves and drawings — p. 1Opens in a new tabHaskel — Refrigerant PumpsOpens in a new tabHaskel — Model 59015Opens in a new tabHaskel — Ultra-Tight SealsOpens in a new tab
More documents in the information centre ←Sources checked: 2026-10-26. Check the revision and configuration when ordering.
YOUR APPLICATION
Your data. Our selection.
- Exact refrigerant code and mixture, if applicable
- Refrigerant state, temperature and inlet/outlet pressures
- Quantity to transfer and target time
- Vacuum requirement and drive/refrigerant separation
- Air pressure and flow, and installation-area requirements
You may attach a specification, drawing or nameplate photo. The site assistant can help organize the data.
Solution selection